Skip to main content

DCX ECDU 600/1200 V1

Coolant Distribution Unit

The Entry ECDU 600/1200 is designed as an accessible, rapid-deployment CDU for customers seeking a cost-effective path into direct liquid cooling. With integrated options and accessories for fast installation, including a built-in Secondary Fluid Network assembly, it provides one of the most affordable entry points into enterprise-grade liquid cooling while preserving the architecture, control philosophy, and integration flexibility of the broader DCX portfolio.

600kW - 1.2 MW cooling & flexible deployment

45°C ultra-efficient cooling with 3°C approach temperature

1500 L/min flow with N+1 pumping system

45-degree warm water cooling, allowing for sustainable, chillerless operations

Overview

The Entry ECDU 600/1200 V1 is designed as a compact, deployment-optimized liquid cooling solution for installations requiring between 600 kW and 1.2 MW of cooling capacity. It addresses the needs of high-density IT environments by providing a scalable thermal management platform that can be matched to different load profiles while maintaining a simplified integration approach.

A key engineering advantage of the Entry ECDU 600/1200 V1 is its pre-integrated Secondary Fluid Network assembly. By incorporating this functionality within the system architecture, the unit significantly reduces on-site integration complexity, shortens installation time, and accelerates commissioning. This approach supports the fastest possible deployment while also helping to improve consistency in system setup, minimize field assembly requirements, and reduce project execution risk.

Features

  • Enterprise ECDU 600/1200 V1 platform with up to 1.2 MW of real cooling capacity
  • Industry-standard rack-based footprint for easier integration into existing facilities
  • Available configurations with N+1 redundant pumps, power supplies, controls.
  • Designed for 45°C cooling operation
  • AT3-class heat exchange performance for improved thermal efficiency
  • Flexible integration with primary and secondary loops through top-entry or technical-floor connections
  • Integrated coolant quality monitoring
  • 12-inch HMI with remote monitoring and group control capability
Get the QuoteGet the Specsheet
Product modelFACILITY DISTRIBUTION UNIT
Cooling capacity [kW]1200#colspan#
Approach temperature [°C]3#colspan#
Operation conditionPrimary sideSecondary side
CoolantFacility waterDI Water
Flow [m3/h]150110
Rated inlet temperature [°C]4053
Rated outlet temperature [°C ]4743
Transport weight [kg / lbs]1 090#colspan#
Operation weight [kg / lbs]1 278#colspan#
Length [mm] | Width [mm] | Height [mm]1200 | 800 | 2400#colspan#
FWS liquid connector style and dimension4" TC Fitting / 4' ASME B16.5 C 100 / DN100 PN16 EN 1092-1#colspan#
TCS liquid connector style and dimension4" TC Fitting / 4' ASME B16.5 C 100 / DN100 PN16 EN 1092-1#colspan#
Power consumption [kW]12,5 kW (N+1)#colspan#
Power specifications3x380-480V AC 50/60 Hz 65,3 A#colspan#
Working environment T&H0~50°C/ RH5~85%#colspan#
Noise Level [dB]70#colspan#

Features

  • Supports a wide range of liquid cooling deployments, from smaller enterprise installations to large-scale AI and hyperscale environments
  • Enables staged capacity growth as IT loads increase
  • Helps preserve uptime through hardware-level redundancy and maintainability
  • Improves heat transfer efficiency and supports energy-conscious cooling design
  • Simplifies deployment with standard form factors and flexible connection options
  • Supports modern data center operating models through integrated monitoring and centralized control
  • Provides a European supply option for advanced direct liquid cooling systems
Get the SpecsheetGet the Quote

System Build

Developed as an enterprise-class platform, the DCX ECDU is designed for reliable operation in mission-critical environments where thermal stability, hydraulic performance, and service continuity are essential. The system architecture supports integration into modern liquid-cooling ecosystems and is intended to simplify deployment, commissioning, and long-term operational management.

The portfolio is built using exclusively European-sourced components, reflecting a strong focus on manufacturing quality, supply-chain transparency, and component consistency. This design approach supports robust performance, high serviceability, and compatibility with the expectations of enterprise data center operators seeking dependable, best-in-class liquid cooling infrastructure.

3°C The lowest approach temperature in the industry
N+1 redundant pumps, power supplies & controls
12-inch HMI with reomte monitoring and group control capacity
Modular and configurable TCS/FWS inlets & outlets

Sustainable high performance computing

As computing power constantly increases, liquid cooling becomes a necessary solution to replace conventional air cooling. DCX HYDRO stands out as the most powerful, compact, sustainable, and energy-efficient data center cooling technology available today.

Get in Touch

We will advise, guide and support – the ideas are always free of charge!

Get your custom solution:

We need basic information to design custom liquid cooling system:

  • Quantity and general specification and dimensions of servers, ICT systems or other to be cooled components, along with power allocation per device or rack.

  • Brief overview of your project along with your main objective: better performance, water savings, energy efficiency, heat reuse, higher density?

  • Preferred liquid cooling technology: direct chip – coldplate system or immersion solution? Planned heat rejection or heat recovery strategy.

  • Country & city nearby planed location for climate data, heat transfer performance & shipping cost estimate.

Explore DCX HYDRO Components

More performance, better reliability, and more comfort. Nothing is better.

DCX HYDRO Universal Coldplates Portfolio

Instead of proprietary custom loops for one server only - a complete portfolio of open direct chip cooling cold-plates that enable you to retrofit any server!

DCX HYDRO Coolant Distribution Units

A wide portfolio of right-sized and custom-configured Coolant Distribution Units available in broad capacities ranging from 100kW to over 5MW capable systems.

DCX Dry Coolers – for every scale of operation

From small proof-of-concept installations, to multi-megawatt deployments. We got it all! See our liquid cooling optimized dry coolers.

Sustainability is in our DNA. Let's change the IT and we will change the world. Together.

We build smart and affordable liquid cooling systems for datacenters and high performance computing.

Everything is designed. Few things are designed well.

We’re DCX, a team of liquid cooling experts. We pride ourselves on being at the forefront of sustainable innovation, developing a unique and smart solutions for data center and telecommunication sector. Our goal is to create future industry standards in liquid cooling technology and to transform the industry forever.

Questions?

You have questions about liquid cooling? We have answers. Contact us. We will design a custom solution free of charge!

Let’s talk!

Every project starts with a vision. We design, manufacture and deliver custom liquid cooling solutions to make your dream a reality.