Small but dense Immersion Crypto Mining Containers as DCX patent pending containerized system with immersion liquid cooling technology is the answer for all the problems that bother industry sized cryptocurrency mining farms. DCX Immersion Mining Containers solves all issues with proprietary, patent-pending granular Immersion Enclosure fluid distribution. The unmatched density of 700 to even 800 ASIC miners installed in immersion enclosures results in 2 to 4 MW power density. Each of our Immersion Containers is equipped with its own second loop pumping and heat exchange station. DCX’s second loop fluid distribution system circulates our ThermaSafe R dielectric Heat Transfer Fluid. Single-phase liquid has 1600 x better heat capacity and 4.5x better heat conductivity than air.
![](https://dcx.eu/wp-content/uploads/DCX-HYDRO-Mining-Container-40_1.png)
Capacity
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus amet
Performance
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus amet
Sustainability
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus amet
Energy Efficiency
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus amet
Overview
DCX Datacenter Container 40
Based on the DCX Scale Out PRO10 Immersion Enclosures and Immersion Rack Systems, they include a complete hydraulic system. Containers are available with maximized miners density (all rack build) or with Low Power Switchgear components to be built-in within the container frame.
- Heat transfer capacity: 2MW Heat Transfer Capacity
- Miner capacity: 256 x S19 / 320 x M56 / 384 x M30
System density options:
- DCX 20HC: 2MW Heat Transfer Performance – 256 x S19 / 320 x M56 / 384 x M30
- DCX 20HC-PD: 1.7 MW Heat Transfer Performance. Turnkey system with full power distribution (switchgear) and accessories included – 192 x S19 / 240 x M56 / 288 x M30
Features
- Hydro CDU System, smart pumps and heat exchanger
- Compact 42U 600x800mm rack
- Hosts 10-12 x M53S++ miners with up to 9.4kW
Ninja Column 1 | Ninja Column 2 |
---|---|
Application | Immersion Mining Farm |
Cooling capacity (Ambient temp=35°C) [kW] | 2000 |
Dimensions [mm] | 12500 x 2580 x 2390 |
Fans | 24 x 800 mm |
Maximum power consumption [kW] | 38.4 |
Power Standard | 400V/3Ph/50hz |
Fittings | 4" / DN100 |
Fluid In / Out [°C] | 60 / 40 |
Nominal volume flow [mᶾ/h] | 43.4 |
Pressure drop | 0.46 |
Features
- Enterprise class system & controls with full redundancy
- Complete loop separation and condensation control
- From 300kw to 1.2MW per single CDU
- From 6 to 28 server racks per single CDU
System Build
DCX Datacenter Container 40
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.
Lorem ipsum dolor sit amet enim. Etiam ullamcorper. Suspendisse a pellentesque dui, non felis. Maecenas malesuada elit lectus felis, malesuada ultricies. Curabitur et ligula. Ut molestie a, ultricies porta urna. Vestibulum commodo volutpat a, convallis ac, laoreet enim. Phasellus fermentum in, dolor. Pellentesque facilisis. Nulla imperdiet sit amet magna. Vestibulum dapibus, mauris nec malesuada fames ac turpis velit, rhoncus eu, luctus et interdum adipiscing wisi. Aliquam erat ac ipsum. Integer aliquam purus. Quisque lorem tortor fringilla sed, vestibulum id, eleifend justo vel bibendum sapien massa ac turpis faucibus orci luctus non, consectetuer lobortis quis, varius in, purus. Integer ultrices posuere cubilia Curae, Nulla ipsum dolor lacus, suscipit adipiscing. Cum sociis natoque penatibus et ultrices volutpat.
![](https://dcx.eu/wp-content/uploads/DCX-HYDRO-Mining-Container-40_2.png)
Get in Touch
We will advise, guide and support – the ideas are always free of charge!
Get your custom solution:
We need basic information to design custom liquid cooling system:
-
Quantity and general specification and dimensions of servers, ICT systems or other to be cooled components, along with power allocation per device or rack.
-
Brief overview of your project along with your main objective: better performance, water savings, energy efficiency, heat reuse, higher density?
-
Preferred liquid cooling technology: direct chip – coldplate system or immersion solution? Planned heat rejection or heat recovery strategy.
-
Country & city nearby planed location for climate data, heat transfer performance & shipping cost estimate.